Low-Temp Storage Get a Selection Plan
Language

-150°C cryogenic refrigerator

Model DW-145W58, temperature zone -60 ~ -150 ℃; DW-150W series 118 ~ 600 liters are optional. Mechanical refrigeration routes, without the use of liquid nitrogen, are used in laboratory research and industrial cryogenic processes.

Model and Temperature Zone

DW-145W58 Basic Configuration
ItemSpecs
ModelDW-145W58
Temperature zone-60 ~ -150℃
Refrigerating modeMechanical cooling without liquid nitrogen
Cabinet structureHorizontal
WarrantyOne year

DW-150W Series Specifications

The DW-150W series sold at -150 ℃ covers 6 volume sections, and the number in the model is the nominal volume (liters). The following table indicates the data in the manufacturer's parameter table.

DW-150W series parameters (manufacturer's parameter list)
ModelOuter dimensions (mm)Inner dimensions (mm)Power (KW)Empty box cooling duration
DW-150W1181500×700×1000540×400×5603.52 hrs
DW-150W2581700×800×1100780×500×6603.5$4.5/Hour
DW-150W3582170×800×11001080×500×6604.52 hrs
DW-150W4552780×800×11001380×500×660103.5 hours
DW-150W5283100×900×14001600×500×66010$4.5/Hour
DW-150W6003300×900×13001800×500×66012$4.5/Hour

Standard working conditions: power supply 380V/50Hz, ambient temperature ≤ 25 ℃, no-load test. The cooling time is the marked value of the manufacturer when the empty box drops to the target temperature zone. The actual loading depends on the heat load of the goods.

-150℃ cryogenic freezer used for shrink-fitting bearings and pins
Industrial cold shrink assembly application diagram (brand material): Bearings, shaft pin parts are assembled after cryogenic cooling, and liquid nitrogen is not used.
-150℃ cryogenic freezer on a machining workshop production line
Field application diagram of machining production line (brand material): The cryogenic process is directly arranged next to the production line.

What it means to not use liquid nitrogen

The -150 ℃ temperature zone used to rely on liquid nitrogen or other low-temperature media to achieve, requiring continuous procurement and replenishment of consumables, and supporting corresponding storage and operation management. The mechanical refrigeration route directly obtains cryogenic cooling through the compression refrigeration system, and the operation process no longer depends on the supply of low-temperature medium.

For laboratories and industrial sites that require long-term continuous operation, this reduces the variable of the consumable supply chain.

Who

  • Cryogenic experiments in research institutes and university laboratories
  • Low-temperature handling of materials and electronics
  • Industrial Cold Fitting and Screen Removal Process
  • Special freezing processes requiring the -150℃ zone

Selection points

The key to the selection of cryogenic models lies in three points: the target temperature that actually needs to be maintained, the time required to cool down to the target temperature, and the effective volume at that temperature. These three items are directly related to the compressor configuration and insulation structure, and need to be confirmed item by item according to the process conditions.

Cryogenic process plan

Define the target temperature and process tempo before deciding on the model.