Low-Temp Storage Get a Selection Plan
Language

Ultra-low temperature refrigeration · Low-temp storage equipment

-150℃ to +20℃ —
the right equipment for every degree

Chiencheng® provides full-range low-temperature storage equipment for biopharma, pharmaceutical distribution, research institutions, fisheries and food processing — covering upright and chest ultra-low freezers, pharmaceutical coolers, medical refrigerators, blood bank refrigerators, mobile freezers, smart vaccine boxes, reagent refrigerators, medical cold rooms and fishery freezers.

16Product lines
-150℃Lowest temperature range
3Utility model patents
7Software copyrights

Product temperature coverage

ChienchengProduct temperature coverage From +20℃ to -150℃ divided into five zones covering pharmaceutical cooling and medical refrigeration, low-temperature freezing, ultra-low storage, deep-freeze storage and cryogenic custom equipment Pharma cooler · Medical fridge +20 ~ 2℃ Low-temp freezing 2 ~ -40℃ Ultra-low storage -40 ~ -86℃ Deep-freeze storage -86 ~ -135℃ Cryogenic custom -135 ~ -150℃ Ambient end Cryogenic end
  • +20 ~ 2℃ Pharmaceutical coolers · medical refrigerators
  • 2 ~ -40℃ Low-temp freezers
  • -40 ~ -86℃ Ultra-low freezers
  • -86 ~ -135℃ Deep-freeze freezers
  • -135 ~ -150℃ Cryogenic custom equipment

Application scenarios

Chiencheng low-temperature storage solutions are deployed across labs, medical institutions, food & beverage, mobile transfer and fishery processing.

Low-temperature storage in a laboratory and biobank

Laboratory & biobank

Long-term safe storage of cells, tissues, blood, DNA/RNA and other samples

Low-temperature storage at a medical facility and pharmacy

Medical institutions & pharma distribution

Compliant storage of vaccines, drugs and blood products — safeguarding pharmaceutical safety

Coffee, tea and craft beer low-temperature scenario

Coffee, tea & craft brewing

Clear-ice cups and fast-ferment beer barrels at low temp — better drink quality and taste

Vehicle-mounted and field low-temperature transport scenario

Mobile & field

Off-grid low-temperature storage for sample transfer, vaccine delivery and fieldwork

Food industry and cold-chain quick-freezing scenario

Food industry & cold chain

Temperature assurance across frozen food processing and cold-chain logistics

Industrial and research cryogenic process scenario

Industry & research cryogenics

Special industrial needs: material cryo-treatment and research cryogenic processes

Vaccine and blood safety low-temperature storage scenario

Vaccine & blood safety

2~8℃ vaccine fridges, 4℃ blood fridges and plasma storage — compliant storage for CDC, blood banks and vaccination sites

Biobank and reagent low-temperature storage scenario

Biobank & reagents

-86℃ ultra-low freezers with racks/boxes covering biobanks, reagents and lab batch management

Fact-based brand strength

The following information can be publicly verified through the National Enterprise Credit Information Publicity System, CNIPA and copyright registration authorities.

3Utility model patents
5Registered trademarks (®)
7Software copyrights
16Product lines
-150℃Lowest temperature range

Technical configuration

The following configuration is from the product manual, covering refrigeration, temperature control, structure and electrical safety.

German EBM quiet fan

EBM fans in the cooling duct run quietly — suitable for long-term indoor operation in labs and medical sites.

Secop compressor

Core compressor from Secop, paired with an optimized single-stage auto-cascade system.

Single-stage auto-cascade

Single compressor auto-cascade — fewer parts, fewer failure points, more stable energy use.

Food-grade 304 stainless liner

304 stainless liner, easy to clean and sanitize — for pharma, food and biomaterial storage.

0.1℃ temperature accuracy

Microcomputer control with 0.1℃ accuracy, multiple alarms and password protection.

187–242V wide voltage

Wide-voltage design for unstable-grid industrial sites and marine environments.

Why choose Chiencheng

Against comprehensive first-tier brands like Haier and Zhongke Meiling, Chiencheng differentiates through deep expertise in the ultra-low-temperature niche.

Deep models validated by SOE

-150℃ capability validated through public tenders of a central SOE engineering group; full specs and parameters available.

Cascade + Stirling dual routes

Mainstream cascade for high-capacity long-term storage; Stirling for small-volume, heat-limited and mobile scenarios.

Enhanced heat dissipation

Optimized cooling structure tolerates 32℃ equipment rooms short-term, reducing summer heat alarms and drift.

Flexible customization

Comm interfaces, door orientation, special alarms and multi-country voltage can be adjusted per project; warranty preserved.

Multi-brand selection agency

Authorized for Haier and Hisense — can supply both brands' full cold-chain lines and recommend by budget and scenario.

Project-based service

Site survey, installation, commissioning and training; deep models with 15-day delivery commitment.

Four steps: from requirement to maintenance

Equipment selection involves site, power, sample type and compliance. We split it into four steps, each with a clear deliverable.

1

Requirements

Confirm stored object, temperature zone, volume, site dimensions and power — and whether customization is needed.

2

Selection & configuration

Match models within the zone; define compressor, liner, monitoring module and alarm options.

3

Delivery & installation

Deliver on schedule, install and commission on site, with operation training and documentation.

4

Operation & support

After-sales response and maintenance; cold-room projects can include remote monitoring and over-temp alarms.

FAQ

The most common questions in purchasing decisions. See the FAQ page for the full list.

How do your devices differ from imported brands?
Mainly in price band and service response. For domestic clients we provide Kunshan-local communication and after-sales, with shorter lead times for customization and small batches. Compare technical specs directly for model differences.
Can you customize non-standard sizes or special zones?
Yes. Medical cold rooms support site customization; ultra-low devices can adjust volume and zone. Provide site dimensions, power and target zone for a feasibility assessment.
Does a cold-room project include a monitoring system?
Yes — intelligent cold-room monitoring with remote temperature, over-temp alarms, energy monitoring and data collection. The software holds 7 software copyrights.
Does business registration equal the device being a medical device?
No. The Class II medical device operating record is a business qualification (may sell Class II devices); whether the device itself is a medical device depends on a registration certificate. -86℃ fridges for medical sample storage need one; research/industrial use does not.

Tell us your zone, volume and site conditions

Provide the stored object, target zone, volume and site dimensions — we'll give model suggestions and a configuration list.